343
Programming Manual
Program 82: Basic Hardware Setup for Extension
82-04: Analogue Station
Initial Data Setup
SA
SB
IN
Description
Use Program 82-04 : Analogue Station Initial Data Setup to define the various basic timers for the 308M/308ME
Card.
Input Data
Prog. No. Item Input Data
Default
Related
Program
82-04-01
Companding method type
0 : μ-law
1 : A-law
1 (A-law)
82-04-02
Ringing frequency
0 : 25Hz
1 : 20Hz
2 : 16Hz
0 (25Hz)
82-04-03
Maximum Break Time
1-255(5ms-1275ms) 2 (10ms)
82-04-04
Minimum Break Time
1-255(5ms-1275ms) 20 (100ms)
82-04-05
Minimum Make Time
1-255(5ms-1275ms) 2 (10ms)
82-04-06
Maximum Make Time
1-255(5ms-1275ms) 20 (100ms)
82-04-07
Maximum Hook Flash Time
1-255(5ms-1275ms) 21 (105ms)
82-04-08
Minimum Hook Flash Time
1-255(5ms-1275ms) 200 (1000ms)
82-04-09
Minimum Ground Flash Time
1-255(5ms-1275ms) 21 (105ms)
82-04-10
Maximum Off-Hook Time
1-255(5ms-1275ms) 21 (105ms)
82-04-11
No detection time after Off-Hook
1-255(5ms-1275ms) 60 (300ms)
82-04-12
No detection time after pulse dial detection
1-255(5ms-1275ms) 70 (350ms)
82-04-13
Loop disconnect time, Reversal time
1-255(5ms-1275ms) 60 (300ms)
82-04-14
Ring, Message wait period time
1-255(5ms-1275ms) 150 (750ms)
Conditions
None
Feature Cross Reference
None