Program 10: System Configuration Setup
10-03: PCB Setup
Programming Manual
IN
SA
SB
Description
Use Program 10-03 : PCB Setup to setup and confirm the Basic Configuration data for each PCB.
When changing a defined terminal type, first set the type to ‘0’ and then plug the new device in to have the system
automatically define it, alternatively redefine the type manually.
Program 10-03 allows the editing of installed units (PCB’s), you can not edit the settings if the slot is unused, install
the PCB first then edit the settings.
Note: The items highlighted in grey are read only and cannot be changed.
Input Data
Slot Number
1-18
1. For HBIU(308M/308E/008E Unit)
Physical Port Number
Extension : 1-8
Trunk : 9-11
Prog. No. Item Input data Default
10-03-01
Terminal Type 0 : No setting
1 : Multi-Line Telephone
2 : Single Line Telephone
10 : DSS Console
13 : Trunk
3-9,11,12 : -Not Used-
0
10-03-02
Logical Port Number(see Note 1) Station : 0-72
Trunk 0-51
0
10-03-03
Transmit Gain Level for SLT 1-63(-15.5…….+15.5dB) 32(0dB)
10-03-04
Receive Gain Level for SLT 1-63(-15.5…….+15.5dB) 32(0dB)
Note 1) Reference and a setup are possible only for a Station port.
2. For 2PGDU Unit
Physical Port Number
1-4
Prog. No. Item Input data Default
10-03-01
Terminal Type
Physical port Number 1-2
0 : No setting
8 : Doorphone
(1-7,10,11 : -Not Used-)
Physical port Number 3-4
0 : No setting
6 : External Speaker
7 : External Trunk Audible
9 : External Music Source(MOH or BGM)
(1-5,8,10,11 : -Not Used-)
Physical port 1-2: 8
Physical port 3-4 : 6
10-03-02
Logical Port Number 0-6
0
10-03-03
Relay setting(see Note 1)
0-4
(0 : Not Used)
Relay No.1 : 1
Relay No.2 : 2
Note 1) The Relays can be assigned up to 2 ports for a 2PGDU Unit.