16
Program 10: System Configuration Setup
10-03: PCB Setup
Programming Manual
IN
SA
SB
3. For BRIU Unit
ISDN Line Number
1-4
Prog. No. Item Input data Default
10-03-01
ISDN Line Mode 0 : No setting
1 : T-Point
2 : S-Point
3 - 5 : Not Used
6 : S-Point(Leased Line)
1
10-03-02
Logical Port Number(see Note 1) [0 : No setting] : 0
[1 : T-Point] : 1 - 8
[2 : S-Point, 6 : S-Point(Leased Line)] : 11-26
0
10-03-03
Connection Type 0 : P-MP
1 : P-P
0
10-03-04
Layer 3 Timer Type(see Note 2)1-5 1
10-03-05
CLIP Information Announcement 0 : Disable
1 : Enable
1
10-03-06
Connection Bus Mode(S-point only) 0 : Extended Passive Bus
1 : Short Passive Bus
1
10-03-07
S-point DID digits 0-4
0
10-03-08
Dial Sending Mode 0 : Enblock sending
1 : Overlap sending
1
10-03-09
Dial Information Element
(Only for Overlap Sending Mode)
0 : Keypad Facility
1 : Called Party Number
1
10-03-10
-Not Used-
--
10-03-11
-Not Used-
--
10-03-12
-Not Used-
--
10-03-13
-Not Used-
--
10-03-14
Service Protocol for S-point
0 : Keypad facility
1 : Special Protocol for Topaz system
0
Note 1) The start port number of a BRI line is displayed. Two logic ports are automatically assigned to a BRI line.
Note 2) Each timer value of Layer3 are set up for every type of Program 81-06 (Trunk mode) and Program 82-06