125
Program 20: System Option Setup
20-01: System Options
Programming Manual
IN
SA
SB
Description
Use Program 20-01 : System Options to set various system options.
Input Data
Prog. No. Item Input data Default Description
Related
Program
20-01-01
Operator Access
Mode
0 : Step
1 : Circular
0 Use this program to set up priority
of a call when calling an operator
telephone.
20-17
20-01-02
Test Message Mode 0 : Call mode
1 : Absent mode
(Busy Tone)
0 Use this program to select the
mode when calling the telephone
which set up the text message.
11-11-14
15-07-08
20-01-03
DSP Sender
Resource Selection
0 : Conference
1 : Caller-ID
2 : MFC
0
20-01-04
-Not Used- - -
20-01-05
DTMF Receive
Active Timer
0-64800(sec.) 10 For OPXs, analogue telephones
and certain analogue trunks (like
DISA), the system attaches a
DTMF receiver to the port for this
interval. The system releases the
receiver after the interval expires.
25-07-01
20-01-06
Alarm Clock
Duration
0-64800(sec.) 30 This interval sets the duration of
the alarm signal.
11-11-12
20-01-07
Callback Ring
Duration
0-64800(sec.) 15 Callback rings an extension for
this interval.
11-12-05
15-07-35
20-01-08
Trunk Queuing
Callback Time
0-64800(sec.) 15 Trunk Queuing callback rings an
extension for this interval.
11-12-05
15-07-35
20-01-09
Callback/ Trunk
queuing Cancel
Time
0-64800(sec.) 64800 The system cancels an extension’s
Callback or Trunk Queuing
request after this interval.
11-12-05
15-07-35
20-01-10
Trunk Guard Timer 0-64800(sec.) 1
Conditions
None
Feature Cross Reference
Refer to above chart