Program 90: Maintenance Program
90-11: System Alarm Report Setup
SA
SB
IN
Description
Use Program 90-11 : System Alarm Report to define the details of the system alarm report.
Input Data
Prog.No. Item Input Data Default
90-11-01
System Alarm Display Telephone
Assign the display KTS port that should receive
system alarms.
Up to 4 digits No setting
90-11-02 Report Method
0- No report
1- Auto-Call (by E-mail) to
outside
0
90-11-03 -Not Used- - -
90-11-04 -Not Used- - -
90-11-05 -Not Used- - -
90-11-06 SMTP Host Name
Up to 255 characters
No setting
90-11-07 SMTP Host Port Number
0-65535
25
90-11-08 To Address
Up to 255 characters
No setting
90-11-09 Reply Address
Up to 255 characters
No setting
90-11-10 From Address
Up to 255 characters
No setting
90-11-11 DNS Primary Address
0.0.0.0-255.255.255.255
0.0.0.0
90-11-12 DNS Secondary Address
0.0.0.0-255.255.255.255
0.0.0.0
90-11-13 Customer Name
Up to 255 characters
No setting
Conditions
None
Feature Cross Reference