234
Programming Manual
Program 25: DID/DISA Setup
25-07: System Timer for DID/DISA
IN
SA
SB
Description
Use Program 25-07 : System Timers for DID/DISA to set the value for the system timers which affect DID and
DISA. Refer to the following chart for a description of each option, its range and default setting.
Input Data
Prog. No. Item Input Data
Default
Related
Program
25-07-01
DISA Dial Tone Time
After answering a DISA trunk, the system waits this
interval for the caller to dial the first digit of the DISA
password. If the caller fails to dial within this interval, the
system drops the call
0-64800(sec) 10 25-04
25-07-02
DID/DISA No Answer Time
A DISA caller can ring an extension for this interval
before the system sets the call as a Ring No Answer.
After this interval expires, the call follows the
programmed Ring No Answer routing (set in Program
25-03 and 25-04).
0-64800(sec) 10 25-04
25-07-03
Disconnect after DID/DISA re-transfer to IRG 0-64800(sec) 60
25-07-04
Calling Time to Automatic answering Telephone set 0-64800(sec) 10
25-07-05
Duration time for Guidance Message by Automatic
answering telephone set
0-64800(sec) 10
25-07-06
Duration time for Guidance Message by ACI Talkie 0-64800(sec) 10
25-07-07
DISA Conversation Warning Tone Time
Determine the length of time a DISA caller can talk
before the Long Conversation tone is heard.
0-64800(sec) 30
25-07-08
DISA Long Conversation Disconnect
This timer determines how long the system will wait
before disconnecting a call after the Long Conversation
tone is heard.
0-64800(sec) 15
25-07-09
DISA Internal Paging Time
This is the maximum length of an Internal Page placed by
a DISA caller. If the Page continues longer than this
interval, the system terminates the DISA call.
0-64800(sec) 30
25-07-10
DISA External Paging Time
This is the maximum length of an External Page placed
by a DISA caller. If the Page continues longer than this
interval, the system terminates the DISA call
0-64800(sec) 30
25-07-11
DID/DISA Answer Delay Timer 0-64800(sec) 0
25-07-12
-Not Used- - -
25-07-13
DID/DISA Busy Tone Interval
If a DISA caller dials a busy extension (and Program
25-04 = 0), the system plays busy tone for this interval
before disconnecting.
0-64800(sec) 5
25-07-14
Delayed DID Answer Timer
Assign the delay time from switching from a normal
incoming status to DID mode. If this time is set to ‘0’,
the call will switch to DID mode immediately.
0-64800(sec) 10

Table of Contents