102
Programming Manual
Program 15: Extension Basic Setup
15-03: Single Line Telephone Basic Data Setup
IN
SA
SB
COP
Description
Use Program 15-03 : Single Line Telephone Basic Data Setup to set up various Single Line Telephone options.
Input Data
Extension Number
Max.4 digits
Prog. No. Item Input data Default Related Program
15-03-01
SLT Signaling Type 0 : Dial Pulse
1 : DTMF
1
15-03-02
-Not Used- -
-
15-03-03
Terminal Type
Enter 1 for this option to allow a single
line port to receive DTMF tones after the
initial call setup. Enter 0 to have the port
ignore DTMF tones after the initial call
setup. For Voice Mail, always enter 1
(e.g., receive DTMF tones).
0 : Normal
1 : Special
0
15-03-04
Flashing
Enables/disables Flash(Hold) for single
line telephones.
0 : Disable
1 : Enable
1
15-03-05
-Not Used- -
-
15-03-06
-Not Used- -
-
15-03-07
Enabled on hook when holding and
press Service code (SLT)
0 : Disable
1 : Enable
1 11-12-45
15-03-08
Answer on hook when holding (SLT)
0 : Disable
1 : Enable
1 11-12-46
15-03-09
Extension Number Display
0 : Disable
1 : Enable
0
15-03-10
Caller Name Display
0 : Disable
1 : Enable
115-03-09
15-03-11
Caller-ID Type for External Module
FSK(0) or DTMF(1) the Caller ID signal
for an external Caller ID module.
Important: If voice mail is used, this
setting must be disabled or the system
integration codes for disconnect will be
incorrect.
0 : FSK
1 : DTMF
0
15-03-12
Fixed Cadence
Select Normal Ring or Fixed
(2sOn/4sOff) Ring when incoming call is
being received.
0 : Normal
1 : Fixed
(2s On/4s Off)
1