– 92 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
BASIC SERVICE FEATURES
08
: Initial Data
BASIC SERVICE FEATURE SETTING DATA
073 Line Fault Detection (Metering Burst)
[Australia Only]
0
1
To provide
Not provided
074 When the line disconnection or short circuit is repaired, the line
fault caused by Metering burst is automatically cleared
[Australia Only]
0
1
Effective
Ineffective
075 PAD control pattern
[For Large type ATTCON]
0
1
Australia
Standard
076 Warning tone is sent to C.O. line, when a station or operator
overrides a busy station connected to a C.O. line.
0
1
Not sent
To send
077 Toll Restriction-Total Digit Count for PB to PB/DP to PB Con-
nection
[Not used in North America]
0
1
To provide
Not provided
078 Trunk seizure sequence when CM35 Y=83: 0
NOTE: When the system is installed with loop-start trunks, it is
important to select the highest available trunk setting
to prevent call collisions.
0
1
Highest available trunk
Lowest available trunk
085 Type of PS/WLAN Terminal No-Answer timer 0
1
As per CM41 Y=0>86
As per CM41 Y=0>01
088 Home PBX Numbering Plan for WCS Roaming
[For PCS]
0
1
Closed Numbering System
Open Numbering System
090 Loop on control after dialing for tandem connection, when the
incoming trunk cannot receive a release signal
0
1
• When the outgoing trunk can detect
an answer signal, loop on is not pro-
vided after dialing
• When the outgoing trunk cannot
detect an answer signal, loop on is
provided after dialing
Loop on is provided
094 Paging access tone sent to station 0
1
To send
Not sent
095 Hook flash (break pulse) sent to Radio Paging equipment from
station
0
1
To send
Not sent
096 Hook flash (break pulse) sent to Voice Paging equipment from
station
0
1
To send
Not sent
Continued on next page
JULY/01/2006
CM08