– 228 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
STATION CLASS-2
13
: Initial Data
Y SETTING DATA
No. MEANING DATA MEANING
06 SMDR/Centralized Billing-CCIS for
outgoing call
0
1
Not provided See CM35 Y=14
To provide
07 Analog data station (FAX, MODEM,
etc.) or ordinary station
See PRECAUTION (2)
0
1
Data station
Ordinary station
08 Send or not ringing signal to the sin-
gle line telephone accommodated on
multiline of D
term
0
1
Not sent ringing signal See CM12 Y=05
Send ringing signal
09 Intra-office connection PAD 0
1
Without PAD
With PAD (6 dB)
Analog SLT connection PAD
[For EU]
[Series 3400]
0
1
Without PAD
With PAD (7 dB)
NOTE: Assign the second data to 1 [with PAD (7dB)] for following countries.
Austria/Belgium/Denmark/Germany/Italy/South Africa/Spain/Sweden/Switzerland/The Nether-
lands/UK/Brazil/China/International
10 Ordinary station or VMS station 0
1
VMS station
See CM41 Y=0>44, 48, 49, CM50 Y=00
Ordinary station
11 BLF indication for Automatic Inter-
com
0
1
To provide
Not provided
12 Secretary station (Boss Secretary
Transfer/Override)
0
1
Secretary station
Ordinary station or Boss station
13 Ordinary station or Front Desk Termi-
nal/Administrative station
0
1
Message Waiting Front Desk Terminal/Administra-
tive station
Ordinary Station
NOTE: MW Lamp of calling station is turned off when Message Waiting Front Desk Terminal answers.
See CM08>233
14 Station Hunting for incoming calls
other than Direct-in Termination calls
0
1
Ineffective
Effective
Continued on next page