CHAPTER 2 PRECAUTION
– 27 – NWA-008844-001 Rev.5.0
91ch2001.fm
Conditions for Using Commands
Continued on next page
CONDITION COMMANDS MEANINGS
Commands which require a
reset of the AP00 card after
data setting.
Set the Make Busy switch
to UP and then DOWN.
CM12 Y=49 Station Class-1
CMD001>20-35, 80-96,
100, 102-107, 109-116,
120, 122-127, 131-136,
140, 142-147, 149-156,
250, 257, 258
SMDR/CIS/PMS Function
CMDD00>3 SMDR Functions (1)/Do Not Disturb Group
Set/Cancel
CMDD01>100-103 SMDR/MCI Functions
CMDD10 Interface Condition for AP00 RS Port
Commands which require a
reset of the DCH card after
data setting.
Set the Make Busy switch
to UP and then DOWN.
CM35 Y=113, 142 Trunk Route Data
CMA9 D-channel Assignment
CMAA Y=06 ISDN Protocol Type for DCH/PRT
Commands which require a
reset of the ICH card after
data setting.
Set the Make Busy switch
to UP and then DOWN.
CMAA Y=06>24, 63 ISDN Terminal Type for ICH
Commands which require a
reset of the DTI/PRT/CCT
card after data setting.
Set the Make Busy switch
to UP and then DOWN.
CM08>644 Basic Service Features
CMAA Y=00, 01, 02, 03,
06, 09, 12, 13
DTI/PRT/CCT Functions
AP00 INITIAL
DCH INITIAL
ICH INITIAL
DTI INITIAL