CHAPTER 2 PRECAUTION
– 28 – NWA-008844-001 Rev.5.0
91ch2001.fm
Conditions for Using Commands
NOTE: Before the MP card is placed into Off-Line mode, the system data backup must be executed by
CMEC Y=6>0:0.
Continued on next page
CONDITION COMMANDS MEANINGS
Commands which require a
reset of the BRT card after
data setting.
Set the Make Busy switch
to UP and then DOWN.
CM08>644 Basic Service Features
CM35 Y=79 Trunk Route Data
CM35 Y=144 ISDN-BRI Layer 1 activation
CM35 Y=283 TEI (Terminal Endpoint Identifier) assign-
ment for ISDN terminals
CMAA Y=06 BRT Functions
Commands which require a
reset of the CIR card after
data setting.
Set the Make Busy switch
to UP and then DOWN.
CM08>489 Basic Service Features
Commands which require a
reset of the CSH card after
data setting.
Set the Make Busy switch
to UP and then DOWN.
CMAD Y=24 Kind of CS/ZT
CMAE Y=00>03, 04, 05,
Y=10, Y=11, Y=15, Y=19,
Y=42
CS/ZT Operation Data Assignment
Commands which can be
used only under Off-Line
mode of the MP card. See
“METHOD OF SETTING
ON-LINE/OFF-LINE
MODE”. Page 31
NOTE
CM00 System Data Memory All Clear
CM01 System Data Memory Partial Clear
CM0B Y=00>90 Remote Site Number Assignment
CMEC Y=4: CCC
CMEC Y=7>00
Maintenance by MAT/CAT
CM4A Y=90 Day/Night Mode Change by System Clock
BRT INITIAL
CIR INITIAL
CSH INITIAL
OFF LINE
NOVEMBER/15/2006
CONDITIONS FOR USING COMMANDS