– 506 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
LOCATION DATA ASSIGNMENT
67
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
02 PAD data between
location group
[Series 3200
R6.2 (R6.2)]
XX ZZ XX: Location
number of
group (00-63)
ZZ : Location
number of
group (00-63)
TT RR
CCC
TT (Transmitter PAD):
+: Gain
–: Loss
00
, 01-08, 81-88
RR (Receiver PAD):
00 , 01-08, 81-88
00 : 0 dB
01 : +2 dB
02 : +4 dB
03 : +6 dB
04 : +8 dB
05 : +10 dB
06 : +12 dB
07 : +14 dB
08 : +16 dB
81 : –2 dB
82 : –4 dB
83 : –6 dB
84 : –8 dB
85 : –10 dB
86 : –12 dB
87 : –14 dB
88 : –16 dB
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CM0A Y=09
CMAD Y=29
(Virtual CS/ZT
for WLAN)
NOTE 1: When setting the PAD data for gaining to the high value, the echo and howling may occur.
NOTE 2: This data setting is valid to the group that is set to “XX” in the first data.
NOTE 3: When this data is set to the location number assigned by CM0A Y=09, there are conditions as follows.
When using the PN-16VCTA-A card, the PAD data setting both of “Transmit” and “Receive” is
valid, but when using PN-16VCTA card, only the PAD data setting of “Receive” is valid.
When using no 16VCT card, the PAD data for “Transmit” and “Receive” cannot be set to the gain
direction.
The data setting of CM0A Y=23, 24 (PAD level of IP-PAD) is overwritten by this data.
NOTE 4: When using the PN-8IPLA card, set the second data in the range of 00 (0 dB) –07 (+14 dB) and
81 (–2 dB) –87 (–14 dB).