– 507 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
LOCATION DATA ASSIGNMENT
67
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
03 Echo Canceller
between location
groups
[Series 3200
R6.2 (R6.2)]
XX ZZ XX: Location
number of
group (00-63)
ZZ : Location
number of
group (00-63)
00
01
NONE
CCC
Echo Canceller OFF
Echo Canceller ON
Echo Canceller ON
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CM0A Y=09
NOTE 1: This data setting is valid to the group that is set to “XX” in the first data.
NOTE 2: When Echo Canceller control for IP-PAD is operated in the system Series 3200 R6.2 or later is used,
this command must be used. The data setting of CM0A Y=21 (Echo Canceller control for IP-PAD) is
invalid.
NOTE 3: When Series 3200 R6.2 or later is used, the Non Linear Processor Control is always provided. The
data setting of CM0A Y=22 (NLP control for IP-PAD) is invalid.
04 Minimum value of
jitter buffer
between location
groups
[Series 3200
R6.2 (R6.2)]
XX ZZ XX: Location
number of
group (00-63)
ZZ : Location
number of
group (00-63)
01
30
NONE
CCC
10 ms.
300 ms.
(10 ms. increments)
10 ms.
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CM0A Y=09
CMAD Y=29
NOTE 1: Assign the value which does not exceed the maximum value of jitter buffer set by CM67 Y=05.
NOTE 2: This data setting is valid to the group that is set to “XX” in the first data.
05 Maximum value of
jitter buffer
between location
groups
[Series 3200
R6.2 (R6.2)]
XX ZZ XX: Location
number of
group (00-63)
ZZ : Location
number of
group (00-63)
01
30
NONE
CCC
10 ms.
300 ms.
(10 ms. increments)
300 ms.
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CM0A Y=09
CMAD Y=29
NOTE 1: Assign the value which exceeds the minimum value of jitter buffer set by CM67 Y=04.
NOTE 2: This data setting is valid to the group that is set to “XX” in the first data.
Continued on next page
~
~
~
~
JULY/01/2006
CM67