– 727 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
2 Fault information
store into memory,
and control of
external alarm
Fault Kind: Occurrence 0
3
NONE
External Alarm Kind
0: Fault Memory
store/No output of
External Alarm
1: Fault Memory
store/External
Alarm is MN
alarm
2: Fault Memory
store/External
Alarm is MJ
alarm
3: Fault Memory
store/External
Alarm Kind is
determined by
standard data
[See 2: External
Alarm Kind (MJ/
MN/– –)]
Page 739
No Fault Memory
store/No External
Alarm output
To assign NONE,
enter CCC.
CM08>450, 451
CM42>01, 50
01 System Initialization
NOTE 1
04 MP-FP/AP communication fail-
ure
08 FP/AP card down
09 Power failure
12 CS/ZT fault occurred
16 Periodic maintenance
20 DTI line failure
21 DCH/BRT/PRT D-channel link
connection failure
22 CCH link connection failure
CCH/IPT link connection fail-
ure
[Series 3300 software
required]
24 Number of faulty trunks was
more than predetermined num-
ber
[Australia Only]
NOTE 2
25 Number of lockout stations was
more than predetermined num-
ber NOTE 3
26 DLC card down
28 SMDR output buffer memory
overflow
2B CS/ZT fault occurred
NOTE 4
2C LAN application fault occurred
[Series 3400]
NOTE 5
Continued on next page
~