– 729 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
2 Fault information
store into memory,
and control of
external alarm
Fault Kind: Restoration 0
3
NONE
External Alarm Kind
0: Fault Memory
store/No output of
External Alarm
1: Fault Memory
store/External
Alarm is MN
alarm
2: Fault Memory
store/External
Alarm is MJ
alarm
3: Fault Memory
store/External
Alarm Kind is
determined by
standard data
[See 2: External
Alarm Kind (MJ/
MN/– –)]
Page 739
No Fault Memory
store/No External
Alarm output
To assign NONE,
enter CCC.
CM08>450, 451
CM42>01, 50
18 FP/AP card returned to normal
condition
19 Power failure returned to nor-
mal condition
30 DTI line returned to normal
condition
31 DCH/BRT/PRT D-channel link
connection returned to normal
condition
32 CCH link connection returned
to normal condition
CCH/IPT link connection
returned to normal condition
[Series 3300 software
required]
34 Number of faulty trunks was
less than predetermined number
[Australia Only]
NOTE 8
35 Number of lockout stations
restored to less than predeter-
mined number NOTE 9
36 DLC card returned to normal
condition
38 SMDR output buffer memory
returned to normal condition
3B CS/ZT returned to normal con-
dition NOTE 10
3C LAN application returned to
normal condition
[Series 3400]
NOTE 5
Continued on next page
~