3-70 Installing the Drive
DC590+ Series DC Digital Drive
Temporary Hanging Bolts
IMPORTANT
We strongly recommend using the temporary mounting hole to hang the unit on the backplate - the phase assemblies are
heavy. This mounting point is not intended for permanent fixing.
Fit M10 x 20mm long bolts to the three "temporary hanging" mounting holes. Screw them in part of the way so that you can still see 12mm of
thread.
The phase assembly will temporarily hang on this portion of thread.
Offering-Up the Phase Assemblies
The phase assemblies are heavy. Use a proper lifting procedure to load them on to the fork lift. Note that the Phase Assembly is fitted with a handle,
opposite the AC terminal, to improve handling.
A stabilising bracket is supplied to steady the phase assembly when using the fork lift. Secure the bracket to the AC terminal using two M10 bolts as
shown below.
For each phase assembly:
Lift the phase assembly
by fork lift and hang it
on the "temporary
hanging" bolt.
Secure the phase
assembly on the
backplate using 4 off
M10 bolts and lock
washers. Hand tighten
only.
Remove the
"temporary hanging"
bolt.
Remove the stabilising
bracket.
Attach the remaining fishplates:
To DC motor terminals A+ and A- (whichever pair are to be used)
To L1, L2 and L3 AC supply terminals

Table of Contents