D-34 Programming
DC590+ Series DC Digital Drive
CONFIGURE DRIVE
This block contains many of the parameters required for configuring the drive.
NOTE The CONFIGURE DRIVE menu on the MMI contains a different set of
parameters, for set-up using the keypad.
CONFIGURE ENABLE: The operation of the Block Diagram is suspended and all Keypad LEDs
will flash whilst CONFIGURE ENABLE = TRUE.
NOTE The CONFIGURE ENABLE parameter is also available in the following MMI
menus for ease of use: CALIBRATION, CONFIGURE I/O
CONFIGURE DRIVE
Parameter
Tag
Range
CONFIGURE ENABLE
39
FALSE / TRUE
Selects
Operating Mode (FALSE) or Configuration Mode (TRUE). Refer to “Modifying a Block Diagram”, page D-1.
NOM MOTOR VOLTS
521
100 to 875 VOLTS
Sets the 100% value for Armature Volts VA. Set this value to match the motor in use. (Refer to ARMATURE V CAL in the CALIBRATION
function block).
ARMATURE CURRENT
523
Product code dependent AMPS
Sets the 100% value for Armature Current IA. Set this value to match the motor in use.
FIELD CURRENT
524
Product code dependent AMPS
Sets the 100% value for Field Current IF. Set this value to match the motor in use. Note: this should be set to a minimum value if in Field Voltage
control - see FLD. CTRL MODE in the FIELD CONTROL function block.
AUTOMATIC SAVE
1220
FALSE/TRUE
When TRUE, changes made to parameters using the operator station are automatically saved to the drive’s non-volatile memory.
DUMP CHANGED
1169
FALSE /TRUE
This parameter is used in conjunction with DUMP MMI (TX) and DUMP BLOCKS. When TRUE, only those parameters that have been modified
from their default value are included in the dump.
UDP USE OP PORT
628
FALSE/TRUE
When TRUE the UDP transfer will be re-directed to the operator station port.
EMULATE 590P
162
0x0000 to 0xFFFF
When non-zero the drive emulates some behaviour of earlier firmware versions of the 590P, (firmware versions 5.x and 7.x). This behaviour affects
the time constants of the PID block, a number of parameters in the Field Control block, speed loop, and the linking of parameters in the function
block diagram (refer to "Emulating Earlier Software Versions". page D-11).
DEBOUNCE DIGIN
1172
FALSE/TRUE
When TRUE the drive adds a 3ms debounce filter to the digital inputs. This affects terminals C3 to C8, B8 and B9. The hardware connection between
terminal B9, (COAST STOP) and the control of the external contactor is not affected.