D-148 Programming
DC590+ Series DC Digital Drive
Operation
Description
FILTER
The OUTPUT is the result of INPUT A passed through a first order low pass infinite impulse response filter with time constant
set by INPUT B, (in seconds).
If INPUT C is not zero then the OUTPUT is se
t to INPUT A.