The Keypad  6-3  
DC590+ Series DC Digital Drive   
Keys for Operating the Drive Locally 
FORWARD/ 
REVERSE 
 
Control
 - Changes the direction of motor rotation when in Local mode, indicated by the display. Selects between 
two jog speeds when in Jog mode. This key has no function in Remote mode. 
 
JOG 
 
Control 
- Runs the motor at a speed determined by the JOG SPEED 1 parameter. When the key is released, the 
Drive returns to “stopped”. Only operates when the Drive is “stopped“ and in Local mode. This key has no 
function in Remote mode. 
RUN 
 
Control
 - Runs the motor at a speed determined by the LOCAL SETPOINT. 
Trip Reset
 - Resets any trips and then runs the motor as above. Only operates when the Drive is in Local mode. 
STOP/RESET 
 
Control
 - Stops the motor. Only operates when the Drive is in Local mode. 
Trip Reset
 - Resets any trips and clears displayed message if trip is no longer active. 
 
Indications 
Keypad Alarm Messages 
An alarm message will be displayed on the MMI when the unit is tripped. 
•  The Drive has tripped. 
The top line indicates a trip has occurred while the bottom line gives the reason for the trip. See 
example opposite. 
Acknowledge the trip message by pressing the E key. Press the STOP/RESET key to restore the Health 
LED.  
Refer to Chapter 7: “Trips and Fault Finding” for trip messages and reasons.