A-24  Serial Communications 
DC590+ Series DC Digital Drive 
Block 6 
PNO (ID)  (MN)  TAG  DATA FORMAT  LIMITS  ACCESS  DESCRIPTION 
BINARY  ASCII    BIT  ASCII  BINARY  MIN TO MAX     
48  30  027    21   xxx.x  0.1/600.0   R/W  Stop time  
49  31  026    21   xxx.x  0.1/600.0  R/W  P-Stop time  
50  32  091    21   xxx.xx  0/200.00  R/W  P-Stop Current Limit  
51  33  029    21   xxx.xx  0/100.00  R/W  Stop Zero Speed Threshold 
52  34  005    21   xxx.xx  -100.00/100.00  R/W  Ramp Input  
53  35  100    21   xxx.xx  -200.00/200.00  R/O  Setpoint Sum Input 1 
54  36  309    21   xxx.xx  -200.00/200.00  R/W  Setpoint Sum Input 0 
55   37      23   xxxxx       
 94  0     0/1   R/W  Aux. Digital Output 1  
 95  1     0/1   R/W  Aux. Digital Output 2  
 96  2     0/1   R/W  Aux. Digital Output 3  
 -  3 - 7       Reserved  
 292  8     0/1   R/W  Sign 0  
 8  9     0/1   R/W  Sign 1  
 9  10     0/1   R/W  Sign 2  
  11 - 15         Reserved  
 
Block 7 
PNO (ID)  (MN)  TAG  DATA FORMAT  LIMITS  ACCESS  DESCRIPTION 
BINARY  ASCII    BIT  ASCII  BINARY  MIN TO MAX     
56   38   055     21   xxx.xx     R/O   Analogue Output 1  
57   39   056     21   xxx.xx     R/O   Analogue Output 2  
58  3A   128    21   xxx.xx  -100.00/100.00  R/W  Aux. Analogue Output 1 
59  3B  129    21   xxx.xx  -100.00/100.00  R/W   Aux. Analogue Output 2  
60   3C   266     21   xxx.xx  0/100.00  R/W   % S-Ramp  
61   3D   264     21   xxx.xx     R/O   Raise / Lower Output 
62   3E   255     21   xxx.xx  -300.00/300.00  R/W   Raise / Lower Reset Value 
63   3F   -     23   xxxxx       
-     261   0      0  1   R/W   Raise / Lower Raise Input  
-     262   1      0  1   R/W   Raise/Lower Lower Input  
-     307   2      0  1   R/W   Raise / Lower Reset