EasyManua.ls Logo

Parker 590+ series - Field Control Mode: Voltage

Parker 590+ series
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-68 Programming
DC590+ Series DC Digital Drive
Functional Description
FIELD CONTROL MODE : VOLTAGE
FIELD ENABLE
ENABLED
TAG#
PARAMETER SETTING
DEFAULT
NOTE (2)
210 FLD.VOLTS RATIO
FIELD
AC VOLTAGE
[VF (AC) RMS]
VOLTAGE
CONTROL
SUPPLY FIELD OUTPUTRATIO
460V
460V
230V
230V
90%
67%
90%
67%
410V
300V
200V
150V
OUTPUT IN VOLTAGE MODE:
183
FIELD DEMAND (%)
186 FLD QUENCH MODE
QUENCH
185
FLD QUENCH DELAY 0.0 SECS
t
DRIVE RUN
NOTE [2]
DISABLING FIELD ENABLE PARAMETER
WILL AUTOMATICALLY OVERRIDE FIELD
FAILURE ALARM.
QUENCH
STAND BY
TO FIELD
SCR FIRING
FLD VOLTAGE VARS
O/P
90.00%
170
169
FIELD ENABLED
x 0.5

Table of Contents

Related product manuals