EasyManua.ls Logo

Parker 590+ series - Wire Sizes and Termination Tightening Torques (Frames 1-5)

Parker 590+ series
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specifications E-29
DC590+ Series DC Digital Drive
Wire Sizes and Termination Tightening Torques (Frames 1-5)
Power cables must have a minimum rating of 1.1 x full load current - EUROPE
Control wiring must have a minimum cross-section area of 0.75mm
2
(18AWG)
UL EUROPE
Terminations
Maximum Tightening
Torque
Recommended Wire Size
Maximum Terminal
Aperture Size (AWG)
Maximum Terminal Aperture Size (mm
2
)
All Units
A1 – A9, B1 – B9, C1 – C9 0.6-0.8Nm (5-7 lb-in.) 14 AWG 12 2.5
Frame 1 15A, 35A UNITS
A+, A- 1.8Nm (16 lb-in) 8-18 AWG 8 10
L1, L2, L3 1.8Nm (16 lb-in) 8-18 AWG 8 10
Grounding terminal 2.0Nm (17 lb-in.) 12 AWG - -
F+, F- 0.8Nm (7.0 lb-in) 14 AWG 12 2.5
L, N, 3, 4, TH1, TH2 0.5Nm (5.0 lb-in) 12 AWG 12 2.5
Frame 2
40A UNITS
A+, A- 5.6Nm (50 lb-in) 8 AWG 2/0 70
L1, L2, L3 5.6Nm (50 lb-in) 8 AWG 2/0 70
Grounding terminal 5.6Nm (50 lb-in) 6 AWG 2/0 70
F+, F- 0.8Nm (7.0 lb-in) 14 AWG 12 2.5
L, N, 3, 4, TH1, TH2 0.5Nm (5.0 lb-in) 12 AWG 12 2.5
70A UNITS
A+, A- 5.6Nm (50 lb-in) 3 AWG 2/0 70
L1, L2, L3 5.6Nm (50 lb-in) 6 AWG 2/0 70
Grounding terminal 5.6Nm (50 lb-in) 6 AWG 2/0 70
F+, F- 0.8Nm (7.0 lb-in) 14 AWG 12 2.5
L, N, 3, 4, TH1, TH2 0.5Nm (5.0 lb-in) 12 AWG 12 2.5
110A UNITS
A+, A- 5.6Nm (50 lb-in) 1/0 AWG 2/0 70
L1, L2, L3 5.6Nm (50 lb-in) 3 AWG 2/0 70
Grounding terminal 5.6Nm (50 lb-in) 6 AWG 2/0 70
F+, F- 0.8Nm (7.0 lb-in) 14 AWG 12 2.5
L, N, 3, 4, TH1, TH2 0.5Nm (5.0 lb-in) 12 AWG 12 2.5