Technical Specifications E-5
DC590+ Series DC Digital Drive
Technical Specifications
Environmental Details
Frame 1 : 0C to +45C
Frame 2 : 0C to +45C
Frame 3 : 0C to +35C
Frame 4 : 0C to +40C
Frame 5 : 0C to +40C
Frame 6 : 0C to +40C
Frame H : 0C to +40C
Operating Temperature
Operating temperature is defined as the ambient temperature to the immediate surround of the Drive, when the Drive and other
equipment adjacent to it is operating at worst case conditions.
Output current values should be derated at 1% per degree Centigrade above rated temperature up to a maximum of 55°C.
Storage Temperature
-25C to +55C
Shipping Temperature
-25C to +70 C
Product Enclosure Rating IP00 (Europe) [Frame 1 unit is IP20]
UL Open Type (North America/Canada)
If the product enclosure is totally enclosed, the exposed metal surface dissipates approximately 50W/m² for a 10°C temperature
rise of internal air above ambient.
Vibration Test Fc of EN60068-2-6
10Hz<=f<=57Hz sinusoidal 0.075mm amplitude
57Hz<=f<=150Hz sinusoidal 1g
10 sweep cycles per axis on each of three mutually perpendicular axis
Altitude If >500 metres (1650 feet) above sea level, derate Motor Power rating by 1% per 200 metres (660 feet) to a maximum of 2,000
metres (6,561 feet)
Humidity
Maximum 85% relative humidity at 40C non-condensing
Atmosphere Non flammable, non corrosive and dust free
Climatic Conditions Class 3k3, as defined by EN60721-3-3 (1995)
Safety
Europe EN61800-5 : 2003, when fitted inside a cubicle
North America/Canada