D-10 Programming
DC590+ Series DC Digital Drive
Simplification of Function Blocks
Some function blocks from previous versions of firmware have been re-arranged to clarify the functionality of each block. The changes are:
SETPOINT SUM 1: The Deadband function has been extracted into a new DEADBAND function block.
5703: This has been split into function blocks 5703 IN and 5703 OUT to improve function block execution order.
AUX IO: This has been split into a new SEQUENCING function block and a smaller AUX I/O block.
PID: The Gain Profile function has been extracted into a new PROFILED GAIN function block.
RAMPS: The Minimum Speed function has been extracted into a new MIN SPEED function block.
In addition, the old Diameter Calc, Taper Calc and Tension & Comp blocks have been combined into a single block called Diameter Calc due to the