The Keypad 6-21
DC590+ Series DC Digital Drive
Menu Shortcuts and Special Key Combinations
Quick Tag Information
Hold down the M key for approximately ½ second in any Menu System parameter to display the Tag
number for that parameter.
Changing the Stack Size (3-button reset)
NOTE This is only necessary if you are installing a new control board on an existing stack.
Power-up the drive holding three keys as described below.
Caution
At this point, the 590+ thinks that it is a 34A model. It is vitally important that it is configured for
the correct power rating or irreparable damage may occur to the drive when it attempts to run the
motor.
Continue to select the correct Product Code rating. Perform a PARAMETER SAVE now (refer to
"
Saving Your Application", page 6-23).
This is the preferred way of selecting a new product code. The available product codes are
restricted to the set of codes that match the stack that the control board is fitted to.
If the product code is changed during the 3-button reset, the following parameters are set to their
default value for the new product code:
Tag 523 ARMATURE CURRENT
Tag 524 FIELD CURRENT
Tag 201 REGEN ENABLE
NOTE The 3-button reset does not cause the default configuration to be loaded.
Hold down the keys opposite:
Power-up the drive, continue
-
to hold for at least 2 seconds
M TO SET PCODE
E TO SAVE PCODE
E TO SAVE PCODE
PRODUCT CODE
DC 4Q 15A
M TO SET PCODE
E TO SAVE PCODE
DIGITAL DC DRIVE
DC 2Q 15A