3-22 Installing the Drive
DC590+ Series DC Digital Drive
Control Connections
Ramp Speed Setpoint
A1
A4
B3
B4
Connect a 10k
potentiometer
between
terminals A1
and B3.
Connect the
wiper to A4.
Uni-directional Speed Setpoint
This connection provides a Uni-Directional Speed Setpoint for non-reversing applications and the 2 Quadrant
controller (591+):
Maximum forward speed setpoint (+100%) = Terminal B3, +10V input
Zero speed setpoint (0%) = Terminal B1, 0V input
Thus, zero speed is at the left (anti-clockwise) position on the potentiometer.
Bi-directional Speed Setpoint
Alternatively, substitute A1 for terminal B4 to scale the input such that:
Maximum forward speed setpoint (+100%) = Terminal B3, +10V input
Maximum reverse speed setpoint (-100%) = Terminal B4, -10V input
Thus, zero speed demand is at the centre position on the potentiometer.
A4 RAMP INPUT
SPEED LOOP
I LIMIT
I LOOP
A6
simplified view
Current Clamp
Speed Setpoint
SPEED FBK
CURR. DMD
In both cases, the Current Limit is controlled via terminal A6 (ANIN5).
NOTE Terminals A1, B1 and C1 (Signal 0V) are the common reference points for all analog signals used
in the drive.
Speed
Demand
Controls
the speed
of the
motor
A4 B3
10K
potentiometer
A6
B4
B3
B4
A4
+10V
-10V
Ramp
Input
B3
1
A4
+10V
0V
Ramp
Input