Serial Communications A-3
DC590+ Series DC Digital Drive
UDP XFER (TX)
This is the transfer of the drive’s settings as an Intel Hex file.
1. Connect the Drive to the host using the appropriate lead.
2. Using a standard communications package prepare the host to receive an ASCII file. Remember to set up the host's serial port first.
3. On the host computer, direct data received on the serial comms port to a file.
4. Start the transfer on the Drive by selecting UDP XFER (TX) on the MMI and pressing the UP () key, as instructed. The drive says
SENDING.
5. When the transfer is finished, terminate the capture of serial data on the host computer.
MMI Dump Procedure
The MMI dump can be used to transfer all of the drive’s parameters or just those that have been changed from the default values. The format of the
data is human readable and may be used as documentation of the drive’s configuration.
DUMP CHANGED
This parameter is used in conjunction with DUMP MMI (TX). When TRUE, only those parameters that have been modified from their default value
are included in the dump.
DUMP MMI (TX)
This is the transfer of all parameters.
1. Connect the Drive to the host using the appropriate lead.
2. Using a standard communications package prepare the host to receive an ASCII file. Remember to set up the host's serial port first.
3. On the host computer, direct data received on the serial comms port to a file.
4. Start the transfer on the Drive by selecting DUMP MMI (TX) on the MMI and pressing the UP () key, as instructed. The drive says
REQUESTED.
5. When the transfer is finished, terminate the capture of serial data on the host computer.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker 590+ series and is the answer not in the manual?

Parker 590+ series Specifications

General IconGeneral
Control ModeSpeed, Torque, Position
Operating Temperature0°C to 40°C
AltitudeUp to 1000 m without derating
Speed Regulation0.01% of base speed
Communication OptionsEthernet, Profibus, CANbus, Modbus, DeviceNet
Feedback OptionsTachometer, Encoder
Protection RatingIP20
Storage Temperature-25°C to 55°C
Relative Humidity5% to 95% (non-condensing)