Serial Communications A-23
DC590+ Series DC Digital Drive
Block 5
PNO (ID) (MN) TAG DATA FORMAT LIMITS ACCESS DESCRIPTION
BINARY ASCII BIT ASCII BINARY MIN TO MAX
40 28 006 21 x.xxxx -3.0000/3.0000 R/W Ratio 1
41 29 007 21 x.xxxx -3.0000/3.0000 R/W Ratio 2
42 2A 086 21 xxx.xx R/O Set Point Sum Output
43 2B 002 21 xxx.x 0.1/600.0 R/W Ramp Accel. Time
44 2C 003 21 xxx.x 0.1/600.0 R/W Ramp Decel. Time
45 2D 085 21 xxx.xx - R/O Ramp Output
46 2E 041 21 xxx.xx -100.00/100.00 R/W Speed Setpoint 4
47 2F 23 xxxxx
082 0 R/O Drive Start
084 1 R/O Drive Enable
122 2 R/O Health Flag
125 3 R/O Ready
4 - 7 Reserved
079 8 R/O At Standstill
112 9 R/O Stall Trip Warning
10 - 15 Reserved