Programming D-15 
DC590+ Series DC Digital Drive   
Functional Description 
 
 - switches the signal source 
between auxilliary and source analog or 
logic tags 
If ADVANCED = OFF  OUTPUT = SOURCE  
If ADVANCED = ON  OUTPUT = INPUT 2 
 - inverts the source logic signal  If ADVANCED = OFF  OUTPUT = INPUT 1 
If ADVANCED = ON  OUTPUT = Logic Inversion of INPUT 1 
 - gives AND-ed result of source logic 
signal and an auxilliary source logic 
signal 
If ADVANCED = OFF  OUTPUT = INPUT 1 
If ADVANCED = ON  OUTPUT = INPUT 1 AND INPUT 2 
 - gives OR-ed result of source logic 
signal and an auxilliary source logic 
signal 
If ADVANCED = OFF  OUTPUT = INPUT 1 
If ADVANCED = ON  OUTPUT = INPUT 1 OR INPUT 2 
 - reverses the sign of the 
source logic signal 
If ADVANCED = OFF  OUTPUT = INPUT 1 
If ADVANCED = ON  OUTPUT = Value sign change of INPUT 1 
 - produces the modulus of the 
source logic signal 
If ADVANCED = OFF  OUTPUT = INPUT 1 
If ADVANCED = ON  OUTPUT = Modulus of INPUT 1 
 - changes destination 
logic signal to TRUE when source analog 
signal is greater than auxilliary analog 
signal 
If ADVANCED = OFF  OUTPUT = INPUT 1 
If ADVANCED = ON  If INPUT 1 ≤ INPUT 2 OUTPUT = 0 
  If INPUT 1 > INPUT 2 OUTPUT = 1