D-14 Programming    
DC590+ Series DC Digital Drive 
ADVANCED 
These two blocks perform some simple 
functions. They are compatible with the special 
Link 11 and Link12 used in earlier versions of 
this product. 
For new configurations, consider using the new 
VALUE and LOGIC function blocks. 
 
ADVANCED 
INPUT 1  686, 688  -32768.00 to 32768.00 % 
General purpose input. 
INPUT 2  687, 689  -32768.00 to 32768.00 % 
 General purpose input. 
ADVANCED  392, 397  OFF/ON 
Controls the OUTPUT parameter. When OFF, OUTPUT is the same as INPUT 1. When ON, OUTPUT is the result of the function selected by 
MODE.  
MODE  393, 398  See below 
This determines which operation is performed on the INPUT 1 and INPUT 2. It can be combined with ADVANCED to dynamically switch the 
OUTPUT between INPUT 1 and the result of the selected function. The functionality of the various MODE selections are shown in the table. 
0 : SWITCH  
1 : INVERTER 
2 : AND     (logic) 
3 : OR      (boolean) 
4 : SIGN CHANGER 
5 : MODULUS 
6 : COMPARATOR 
OUTPUT  712, 713