EasyManua.ls Logo

Parker 590+ series - Advanced

Parker 590+ series
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-14 Programming
DC590+ Series DC Digital Drive
ADVANCED
These two blocks perform some simple
functions. They are compatible with the special
Link 11 and Link12 used in earlier versions of
this product.
For new configurations, consider using the new
VALUE and LOGIC function blocks.
ADVANCED
Parameter
Tag
Range
INPUT 1 686, 688 -32768.00 to 32768.00 %
General purpose input.
INPUT 2 687, 689 -32768.00 to 32768.00 %
General purpose input.
ADVANCED 392, 397 OFF/ON
Controls the OUTPUT parameter. When OFF, OUTPUT is the same as INPUT 1. When ON, OUTPUT is the result of the function selected by
MODE.
MODE 393, 398 See below
This determines which operation is performed on the INPUT 1 and INPUT 2. It can be combined with ADVANCED to dynamically switch the
OUTPUT between INPUT 1 and the result of the selected function. The functionality of the various MODE selections are shown in the table.
0 : SWITCH
1 : INVERTER
2 : AND (logic)
3 : OR (boolean)
4 : SIGN CHANGER
5 : MODULUS
6 : COMPARATOR
OUTPUT 712, 713
.xx V
Result of the selected function on the inputs.

Table of Contents

Related product manuals