3-94 Installing the Drive
DC590+ Series DC Digital Drive
Line Choke Installation Drawings
IMPORTANT
Always use the specified ac line choke with the Drive.
Parker
Part Number
Drive
Rating
Weight
Dimensions (mm) Mtg
Hole
Terminal
(kg) A B C D E F Ø Ø
For use without EMC Filters
Frame 1
CO466448U015
15A 1 67 60 80 40
64
8 7 M8
CO466448U040
35A 2.5 127
70 155
48
140
7.5
7 M8
Frame 2
CO466448U040
40A 2.5 127
70 155
48
140
7.5
7 M8
CO466448U070
70A 4.5 127
76 155
55
140
7.5
7 M8
CO466448U110
110A 7.5 160
100
190
75
170
10
9 M8
CO466448U165
165A 7.5 160
102
190
76
170
10
9 M8
For use with EMC filters
Frame 1
CO466449U015
15A 4.5 127
90 155
68
140
7.5
7 M8
CO466449U040
35A 8 160
100
190
75
170
10
9 M8
Frame 2
CO466449U040
40A 8 160
100
190
75
170
10
9 M8
CO466449U070
70A 10 160
105
190
83
170
10
9 M8
CO466449U110
110A 14 160
125
190
103
170
10
9 M8
CO466449U165
165A 28 225
200
240
176
150
45
15 M8