6-22 The Keypad   
DC590+ Series DC Digital Drive 
Resetting to Factory Defaults (2-button 
reset) 
Power-up the drive holding two keys as described below. 
The drive is now safely configured with the default settings detailed in this manual for the existing 
product code. 
The default configuration is not automatically saved to non-volatile memory, so you must perform a 
PARAMETER SAVE (refer to "
Saving Your Application", page 6-23). 
 
 
 
 
Cloning Feature 
The Keypad can be used to transfer all 
parameters from a drive to another of the same 
rating. You can also use the Keypad to store a 
back-up of the drive's parameter settings. 
SAVE TO OP will upload all parameter settings 
from the drive to the Keypad. 
LOAD FROM OP will download all parameter 
settings from the Keypad to the drive.