C-10 Parameter Specification Tables
DC590+ Series DC Digital Drive
Tag Mn MMI Block Name MMI Parameter Name Minimum Maximum Default Units Range Notes
256 h4 RAISE/LOWER INCREASE RATE 0.1 600.0 10.0 s V0 W0
257 h5 RAISE/LOWER DECREASE RATE 0.1 600.0 10.0 s V0 W0
258 h6 RAISE/LOWER MIN VALUE -300.00 300.00 -100.00 % V0 W0
259 h7 RAISE/LOWER MAX VALUE -300.00 300.00 100.00 % V0 W0
260 h8 LINK 27 RAISE/LOWER DEST 0 1276 0 V0 W2
261 h9 RAISE/LOWER RAISE INPUT 0 1 0 V0 W0
262 ha RAISE/LOWER LOWER INPUT 0 1 0 V0 W0
263 hb ALARMS STALL THRESHOLD 0.00 200.00 95.00 % V1 W0
264 hc RAISE/LOWER RAISE/LOWER O/P 0.00 0.00 0.00 % V0 W4
266 he RAMPS % S-RAMP 0.00 100.00 2.50 % V1 W0
268 hg SPEED LOOP MODE 0 3 0
0: DISABLED
1: SPD FBK DEP
2: SPD ERR DEP
3: CUR DMD DEP
V0 W0
269 hh SPEED LOOP SPD BRK1 (LOW) 0.00 100.00 1.00 % V0 W0
270 hi SPEED LOOP SPD BRK2 (HIGH) 0.00 100.00 5.00 % V0 W0
271 hj SPEED LOOP PROP. GAIN 0.00 200.00 5.00 V0 W0
272 hk SPEED LOOP INT.TIME.CONST 0.001 30.000 0.500 s V0 W0
274 hm SPEED LOOP I GAIN IN RAMP 0.0000 2.0000 1.0000 V0 W0
284 hw SPEED LOOP ZERO SPD. LEVEL 0.00 200.00 0.50 % V0 W0
285 hx SPEED LOOP ZERO IAD LEVEL 0.00 200.00 1.50 % V0 W0
286 hy RAMPS RAMPING THRESH. 0.00 100.00 0.50 % V1 W0
287 hz RAMPS AUTO RESET 0 1 1
0: DISABLED
1: ENABLED
V1 W0
288 i0 RAMPS EXTERNAL RESET 0 1 0
0: DISABLED
1: ENABLED
V1 W0
289 i1 SPEED LOOP SETPOINT 1 -105.00 105.00 0.00 % V0 W0
290 i2 SPEED LOOP SETPOINT 2 (A3) 0.00 0.00 0.00 % V0 W4
291 i3 SPEED LOOP SETPOINT 3 -105.00 105.00 0.00 % V0 W0
292 i4 SETPOINT SUM 1 SIGN 0 0 1 1
0: NEGATIVE
1: POSITIVE
V1 W0
293 i5 LINK 28 RAMP O/P DEST 0 1276 291 V0 W2
294 i6 LINK 29 SPT SUM 1 DEST 0 1276 289 V0 W2
297 i9 SPEED LOOP SPEED ERROR 0.00 0.00 0.00 % V0 W4
298 ia FEEDBACKS CURRENT FEEDBACK 0.00 0.00 0.00 % V0 W4