Parameter Specification Tables C-17
DC590+ Series DC Digital Drive
Tag Mn MMI Block Name MMI Parameter Name Minimum Maximum Default Units Range Notes
500 nw TEC OPTION TEC OPTION TYPE 0 15 0
0: NONE
1: RS485
2: PROFIBUS DP
3: LINK
4: DEVICE NET
5: CAN OPEN
6: LONWORKS
7: CONTROLNET
8: MODBUS PLUS
9: ETHERNET
10: TYPE 10
11: TYPE 11
12: TYPE 12
13: TYPE 13
14: TYPE 14
15: TYPE 15
V0 W0
501 nx TEC OPTION TEC OPTION IN 1 -32768 32767 0 V0 W0
502 ny TEC OPTION TEC OPTION IN 2 -32768 32767 0 V0 W0
503 nz TEC OPTION TEC OPTION IN 3 -32768 32767 0 V0 W0
504 o0 TEC OPTION TEC OPTION IN 4 -32768 32767 0 V0 W0
505 o1 TEC OPTION TEC OPTION IN 5 -32768 32767 0 V0 W0
506 o2 TEC OPTION TEC OPTION FAULT 0 5 0
0: NONE
1: PARAMETER
2: TYPE MISMATCH
3: SELF TEST
4: HARDWARE
5: MISSING
V0 W4
507 o3 TEC OPTION TEC OPTION VER 0x0000 0xFFFF 0x0000 V0 W4
508 o4 TEC OPTION TEC OPTION OUT 1 0 0 0 V0 W4
509 o5 TEC OPTION TEC OPTION OUT 2 0 0 0 V0 W4
510 o6 DRIVE INFO PRODUCT CODE 0 104 3
0: INVALID
1: DC 4Q 15A
2: DC 2Q 15A
3: DC 4Q 35A
4: DC 2Q 35A
5: DC 4Q 40A
6: DC 2Q 40A
7: DC 4Q 55A
8: DC 2Q 55A
V0 W3