Parameter Specification Tables C-35
DC590+ Series DC Digital Drive
Tag Mn MMI Block Name MMI Parameter Name Minimum Maximum Default Units Range Notes
1252 mE ALARM HISTORY ALARM 7 0x0000 0xFFFF 0x0000 V0 W4
1253 mF ALARM HISTORY ALARM 8 0x0000 0xFFFF 0x0000 V0 W4
1254 mG ALARM HISTORY ALARM 9 0x0000 0xFFFF 0x0000 V0 W4
1255 mH ALARM HISTORY ALARM 10 OLDEST 0x0000 0xFFFF 0x0000 V0 W4
1259 mL PID HI RES PROP GAIN 0.000 100.000 0.000 V1 W0
1265 mR ? POSITIVE LIMIT 0.00 250.00 250.00 ? ?
1266 mS ? NEGATIVE LIMIT -250.00 0.00 -250.00 ? ?
1267 mT ENCODER 1 ENCODER TYPE 0 1 1
0: CLOCK/DIRECTION
1: QUADRATURE
V0 W1
1268 mU ENCODER 2 ENCODER TYPE 0 1 1
0: CLOCK/DIRECTION
1: QUADRATURE
V0 W1
1273 mZ FIELD CONTROL BEMF SOURCE 0 1 0
0: LOCAL BEMF
1: BEMF INPUT
V1 W1
1274 nA FIELD CONTROL BEMF INPUT -200.00 200.00 0.00 % V1 W0
1275 nB CURRENT LOOP ISOL DMD SOURCE 0 1 0
0: ANIN 2 (A3)
1: FIELD I DEMAND
V1 W1
1276 nC AUTOTUNE ERROR TYPE 0 11 0
0: NO ERROR
1: OVER SPEED
2: FIELD ERROR
3: PULSE WIDTH
4: OVER CURRENT
5: TIMEOUT
6: AUTOTUNE ABORTED
7: FIRING ANGLE
8: PEAK/AVER. RATIO
9: UNBALANCED BRID.
10: NULL AVERAGE CUR
11: THYRISTOR OFF
V1 W4