Programming D-23
DC590+ Series DC Digital Drive
ANALOG INPUTS
Parameter
Tag
Range
CALIBRATION 230, 233, 236, 239, 242 -3.0000 to 3.0000
The analog input scaling ratio. For a value of 1.0, 10V = 100%.
MAX VALUE 231, 234, 237, 240, 243 -300.00 to 300.00 %
The maximum value of the scaled analog input.
MIN VALUE 232, 235, 238, 241, 244 -300.00 to 300.00 %
The minimum value of the scaled analog input.
OUTPUT 674, 493, 675, 676, 677
.xx %
These parameters is the output diagnostic ANALOG INPUT 1 to ANALOG INPUT 5. Note by default 10V = 100%. To obtain a different range,
adjust the CALIBRATION, MAX VALUE and MIN VALUE parameters.
ANIN 1 (A2) to ANIN 5 (A6) 50, 51, 52, 53, 54
.xx VOLTS
Actual volts measured on the analog input.