Programming D-75
DC590+ Series DC Digital Drive
JOG/SLACK
Parameter
Tag
Range
RAMP RATE
355
0.1 to 600.0 s
The ramp rate used while jogging. This is independent of the main ramp rate during normal running. The acceleration and deceleration times in jog
are always equal.
OPERATING MODE
212
See below
Refer to Chapter 6: "The Keypad" - The Keypad Menus (DIAGNOSTICS).
0 : STOP
1 : STOP
2 : JOG SP. 1
3 : JOG SP. 2
4 : RUN
5 : TAKE UP SP. 1
6 : TAKE UP SP. 2
7 : CRAWL
JOG/SLACK OUTPUT 698 ___.00 %
The setpoint combined with the JOG / SLACK function.
Functional Description
NOTE The setpoint column in the table below refers to the Ramp Input ONLY, as indicated in the table. Any "direct" setpoints present will also add
to this setpoint to make the total speed setpoint. If you don't want this to happen, for example during jogging, then disconnect the direct
setpoint(s) during the appropriate conditions.
Setpoint Selection Table
OPERATING MODE [212] - diagnostic
Start C3
Jog C4
MODE [228]
Ramp Input
Ramp Time
Contactor
0 : STOP
OFF
OFF
False
Setpoint Default OFF
1 : STOP
OFF
OFF
True
Setpoint Default OFF
2 : JOG SP. 1 (inch/jog 1)
OFF
ON
False
JOG SPEED 1 RAMP RATE ON
3 : JOG SP. 2 (inch/jog 2)
OFF
ON
True
JOG SPEED 2 RAMP RATE ON
4 : RUN
ON
OFF
False
Setpoint Default ON
5 : TAKE UP SP. 1 (take-up slack 1)
ON *
ON *
False
Setpoint + TAKE UP 1 Default ON
6 : TAKE UP SP. 2 (take-up slack 2)
ON
OFF
True
Setpoint + TAKE UP 2 Default ON
7 : CRAWL
ON *
ON *
True
CRAWL SPEED Default ON
* Start (C3) and Jog (C4) must be applied (ON) simultaneously in the cases of TAKE UP SP.1 and CRAWL.