C-64 Parameter Reference
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Encoder Speed
1516
Monitor::Inputs and Outputs
Parameters::Option IO::Encoder
x.
Min to Max
RPM
NEVER
The speed measured by the encoder, in revolutions per minute.
Encoder Count Reset
1517
Same as PNO 1511
FALSE
ALWAYS
If set to TRUE resets the encoder count.
Encoder Count Init
1783
Parameters::Option IO::Encoder
TRUE
ALWAYS
If set to TRUE the encoder count is reset to zero when the drive powers up.
Encoder Count
1518
Same as PNO 1516
Min to Max
NEVER
This parameter shows the encoder count, which is a 32 bit counter that will increment and decrement with the encoder pulses, up to
2^31 or down to -2^31.