C-132 Parameter Reference
AC30 series Variable Speed Drive
PMAC Base Volt
1387
Setup::Motor Control::Motor Data PMAC
Parameters::Motor Control::PMAC Motor
Data
400.00
0.00 to 1000.00
V
ALWAYS
Rated motor rated voltage in Volt rms
PMAC Encoder Offset
1808
Setup::Motor Control::Motor Data
PMAC
Parameters::Motor
Control::PMAC Motor Data
0.0
-180.0 to 180.0
deg
ALWAYS
Only available if 1533 Control Type = ENCODER FEEDBACK
Electrical position Offset between encoder Zero position and motor Back EMF
Automatically set up if Alignment sequence runs and completed
PMAC Wiring
1809
Setup::Motor Control::Motor Data
PMAC
Monitor::Motor and Drive
Parameters::Motor
Control
::PMAC Motor Data
0
Same as PNO 1804
ALWAYS
Only available if 1533 Control Type = ENCODER FEEDBACK
Wiring direction of the motor phase :
- STANDARD : U V W
- REVERSE : U W V
Allow to change connection of phase V and W internally to the drive. No external action required.
Automatically set up if Alignment sequence runs and completed.
Changing this parameter will change the direction of motor rotation. Please verify if the new direction is compatible with your
application.