EasyManuals Logo

Parker AC30 series User Manual

Parker AC30 series
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #395 background imageLoading...
Page #395 background image
Parameter Reference C-213
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Short Overload Level
0346
Parameters::Motor Control::Stack Inv
Time
x.
0 to 200
%
NEVER
Overload value in % of the stack amps for short overload condition(*)
Short Overload Time
0347
Parameters::Motor Control::Stack Inv
Time
0.000 to 10000.000
s
NEVER
Maximum duration under short overload condition (typically 3s)
Inv Time Aiming Point
0348
Parameters::Motor Control::Stack Inv
Time
105.00
0.00 to 125.00
%
ALWAYS
Current in % where the power stack can undertake the load current permanently
Inv Time Output
0349
Parameters::Motor Control::Stack Inv
Time
x.
0 to 600
%
NEVER
Actual output current limit as a % of the stack current
Inv Time Up Rate
0350
Parameters::Motor Control::Stack Inv
Time
5.000
0.000 to 120.000
s
STOPPED
Ramp value to ramp up current when overload condition disappears
Inv Time Down Rate
0351
Parameters::Motor Control::Stack Inv
Time
5.000
0.000 to 120.000
s
STOPPED
Ramp value to reach the aiming point under prolonged overload condition
Inv Time Warning
0352
Parameters::Motor Control::Stack Inv
Time
NEVER
The protection starts to integrate overload conditions

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals