Parameter Reference C-233
AC30 series Variable Speed Drive
WQ: The write qualifier.
ALWAYS
The parameter has no write restrictions
STOPPED
The parameter is only writable when the motor is not being controlled
CONFIG The parameter may only be written when the drive is in CONFIGURATION mode (NOT READY TO
SWITCH ON)
NEVER
The parameter is monitor only
View: Indicates when the parameter is visible on the GKP or the Web page.
Parameters that are not relevant to the current drive’s configuration may be hidden regardless of the View level.
OPERATOR
The parameter is always visible.
TECHNICIAN
The parameter is visible when the view level is set to OPERATOR or TECHNICIAN
ENGINEER
The parameter is visible when the view level is set to OPERATOR, TECHNICIAN or ENGINEER
Mbus: The Modbus register number corresponding the this PNO.
Notes:
1. The parameter is automatically saved before power down
2. Input parameter is not saved.
3. Output parameter is saved.
4. Parameter is hidden depending on the drive configuration.
5. Parameter is cloned as part of the “Other Parameters” group.
6. Parameter is cloned as part of the “Power Parametersgroup.
7. Parameter is cloned as part of the “Drive Unique” group.
8. Parameter availability depends on the application selected.
9. Parameter is modified by an auto-tune.