C-244 Parameter Reference
AC30 series Variable Speed Drive
2:NOT QUICKSTOP
3:ENABLE OPERATION
7:RESET FAULT
8:EXTERNAL FAULT
10:USE COMMS CONTROL
11:USE COMMS REFERENCE
12:USE JOG REFERENCE
13:REVERSE DIRECTION
14:AUTO INITIALISE
15:EVENT TRIGGERED OP
0645
Control Word.SWITCH ON
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01817
0646
Control Word.ENABLE VOLTAGE
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01819
0647
Control Word.NOT QUICKSTOP
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01821
0648
Control Word.ENABLE OPERATION
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01823
0652
Control Word.RESET FAULT
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01831
0653
Control Word.EXTERNAL FAULT
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01833
0655
Control Word.USE COMMS CONTROL
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01837
0656
Control Word.USE COMMS REFERENCE
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01839
0657
Control Word.USE JOG REFERENCE
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01841
0658
Control Word.REVERSE DIRECTION
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01843
0659
Control Word.AUTO INITIALISE
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01845
0660
Control Word.EVENT TRIGGERED OP
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01847
0661
Status Word
Parameters::Motor Control::Sequencing
WORD
(bitfield)
0:READY TO SWITCH ON
1:SWITCHED ON
2:OPERATION ENABLED
3:FAULTED
4:VOLTAGE ENABLED
5:QUICKSTOP INACTIVE
6:SWITCH ON DISABLED
9:CONTROL FROM COMMS
12:JOG OPERATION
13:REVERSE OPERATION
14:REFERENCE FROM COMMS
15:STOPPING
NEVER
TECHNICIAN
01849
0662
Status Word.READY TO SWITCH ON
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01851
0663
Status Word.SWITCHED ON
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01853
0664
Status Word.OPERATION ENABLED
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01855
0665
Status Word.FAULTED
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01857
0666
Status Word.VOLTAGE ENABLED
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01859
0667
Status Word.QUICKSTOP INACTIVE
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01861
0668
Status Word.SWITCH ON DISABLED
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01863
0671
Status Word.CONTROL FROM COMMS
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01869
0674
Status Word.JOG OPERATION
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01875
0675
Status Word.REVERSE OPERATION
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01877
0676
Status Word.REFERENCE FROM COMMS
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01879
0677
Status Word.STOPPING
Parameters::Motor Control::Sequencing
BOOL
NEVER
TECHNICIAN
01881
0678
Sequencing State
Parameters::Motor Control::Sequencing
USINT
(enum)
0:NOT READY TO SWITCH ON
1:SWITCH ON DISABLED
2:READY TO SWITCH ON
3:SWITCHED ON
4:OPERATION ENABLED
5:QUICKSTOP ACTIVE
6:FAULT REACTION ACTIVE
7:FAULTED
NEVER
TECHNICIAN
01883
0679
Switch On Timeout
Parameters::Motor Control::Sequencing
TIME
0.000
0.000 to 100.000
s
ALWAYS
TECHNICIAN
01885
0680
App Reference
Parameters::Motor Control::Sequencing
REAL
0.00
-110.00 to 110.00
%
ALWAYS
TECHNICIAN
01887
0681
Comms Reference
Parameters::Motor Control::Sequencing
REAL
0.00
-110.00 to 110.00
%
ALWAYS
TECHNICIAN
01889
0682
Reference
Parameters::Motor Control::Sequencing
REAL
x.xx
-110.00 to 110.00
%
NEVER
OPERATOR
01891
0686
Anout 01 Scale
Setup::Inputs and Outputs::Base IO
Parameters::Inputs And Outputs::IO Configure
REAL
1.0000
Min to Max
ALWAYS
OPERATOR
01899
0687
Boot Version Number
Parameters::Device Manager::Drive info
WORD
NEVER
ENGINEER
01901
0688
Drive Diagnostic
Parameters::Device Manager::Drive info
USINT
(enum)
0:OK
1:STACK NOT CONNECTED
2:STACK DATA CORRUPT
3:UNKNOWN STACK
4:STACK MISMATCH
NEVER
OPERATOR
01903
0689
PMAC Flycatching Enable
Parameters::Motor Control::PMAC Flycatching
BOOL
FALSE
ALWAYS
TECHNICIAN
4
01905
0690
PMAC Fly Search Mode
Parameters::Motor Control::PMAC Flycatching
USINT
(enum)
0
Same as PNO 312
ALWAYS
TECHNICIAN
4
01907