Parameter Reference C-249
AC30 series Variable Speed Drive
0850
Warnings 1 - 32.21 PHASE FAIL
Same as PNO 829
BOOL
NEVER
OPERATOR
02227
0851
Warnings 1 - 32.22 VDC RIPPLE
Same as PNO 829
BOOL
NEVER
OPERATOR
02229
0852
Warnings 1 - 32.23 BASE MODBUS BREAK
Same as PNO 829
BOOL
NEVER
OPERATOR
02231
0853
Warnings 1 - 32.24 24 V OVERLOAD
Same as PNO 829
BOOL
NEVER
OPERATOR
02233
0854
Warnings 1 - 32.25 PMAC SPEED ERROR
Same as PNO 829
BOOL
NEVER
OPERATOR
02235
0855
Warnings 1 - 32.26 OVERSPEED
Same as PNO 829
BOOL
NEVER
OPERATOR
02237
0856
Warnings 1 - 32.27 STO ACTIVE
Same as PNO 829
BOOL
NEVER
OPERATOR
02239
0857
Warnings 1 - 32.28 FEEDBACK MISSING
Same as PNO 829
BOOL
NEVER
OPERATOR
02241
0858
Warnings 1 - 32.29 INTERNAL FAN FAIL
Same as PNO 829
BOOL
NEVER
OPERATOR
02243
0859
Warnings 1 - 32.30 CURRENT SENSOR
Same as PNO 829
BOOL
NEVER
OPERATOR
02245
0860
Warnings 1 - 32.31 POWER LOSS STOP
Same as PNO 829
BOOL
NEVER
OPERATOR
02247
0861
Warnings 1 - 32.32 SPEED SENSOR
Same as PNO 829
BOOL
NEVER
OPERATOR
02249
0890
Maintenance Warnings
Parameters::Trips::Maintenance Monitor
WORD
NEVER
OPERATOR
02307
0891
Maintenance Reporting
Parameters::Trips::Maintenance Monitor
WORD
FFFF
ALWAYS
TECHNICIAN
02309
0892
Maintenance Reset
Parameters::Trips::Maintenance Monitor
WORD
0000
ALWAYS
ENGINEER
2
02311
0893
Ambient Temperature
Parameters::Trips::Maintenance Monitor
REAL
25.0
-20.0 to 70.0
°C
ALWAYS
TECHNICIAN
02313
0894
IM Wiring
Parameters::Motor Control::Induction Motor Data
BOOL
FALSE
STOPPED
OPERATOR
6
02315
0895
Recent Trips
Parameters::Trips::Trips History
ARRAY[0..9]
NEVER
OPERATOR
02317
0896
Recent Trips[0]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02319
0897
Recent Trips[1]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02321
0898
Recent Trips[2]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02323
0899
Recent Trips[3]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02325
0900
Recent Trips[4]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02327
0901
Recent Trips[5]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02329
0902
Recent Trips[6]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02331
0903
Recent Trips[7]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02333
0904
Recent Trips[8]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02335
0905
Recent Trips[9]
Parameters::Trips::Trips History
USINT
(enum)
Same as PNO 696
NEVER
OPERATOR
1
02337
0906
Stall Limit Type
Parameters::Trips::Stall Trip
USINT
(enum)
2
0:TORQUE
1:CURRENT
2:TORQUE OR CURRENT
ALWAYS
TECHNICIAN
02339
0907
Stall Time
Parameters::Trips::Stall Trip
TIME
90.000
0.100 to 2000.000
s
ALWAYS
TECHNICIAN
6
02341
0908
Control Screen Mode
Parameters::Device Manager::Soft Menus
USINT
(enum)
1
0:DISABLED
1:AUTO
2:CUSTOM
STOPPED
ENGINEER
02343
0909
Stall Torque Active
Parameters::Trips::Stall Trip
BOOL
NEVER
TECHNICIAN
02345
0910
Stall Current Active
Parameters::Trips::Stall Trip
BOOL
NEVER
TECHNICIAN
02347
0911
Stall Speed Feedback
Parameters::Trips::Stall Trip
REAL
x.
-200 to 200
%
NEVER
ENGINEER
02349
0912
VDC Ripple Filter TC
Parameters::Trips::VDC Ripple
TIME
1.000
0.100 to 100.000
s
ALWAYS
ENGINEER
02351
0913
Max VDC Ripple
Parameters::Trips::VDC Ripple
REAL
x.
0 to 500
V
NEVER
ENGINEER
02353
0914
VDC Ripple Trip Delay
Parameters::Trips::VDC Ripple
TIME
0.000 to 300.000
s
NEVER
ENGINEER
02355
0915
VDC Ripple Trip Hyst
Parameters::Trips::VDC Ripple
REAL
10
0 to 50
V
ALWAYS
ENGINEER
02357
0916
VDC Ripple Sample
Parameters::Trips::VDC Ripple
TIME
0.009
0.001 to 0.100
s
ALWAYS
ENGINEER
02359
0917
VDC Ripple Level
Parameters::Trips::VDC Ripple
REAL
x.
0 to 500
V
NEVER
ENGINEER
02361
0918
Filtered VDC Ripple
Parameters::Trips::VDC Ripple
REAL
x.
0 to 500
V
NEVER
ENGINEER
02363
0919
Ethernet State
Monitor::Communications::Base Ethernet
Parameters::Base Comms::Ethernet
USINT
(enum)
0:INITIALISING
1:NO LINK
2:RESOLVING IP
3:RESOLVING DHCP
4:RESOLVING AUTO
5:RESOLVED IP
6:STOPPING DHCP
7:DUPLICATE IP
8:FAULT
NEVER
OPERATOR
02365
0920
MAC Address
Same as PNO 919
STRING[17]
NEVER
OPERATOR
02367
0926
IP Address
Same as PNO 919
DWORD
(IP addr)
NEVER
OPERATOR
02379