VNA GUI reference
R&S
®
ZNL/ZNLE
317User Manual 1178.5966.02 ─ 20
The "Scale Values" settings depend on the current trace format (diagram type)
because not all diagrams can be scaled in the same way:
In Cartesian diagrams, all scale settings are available.
In circular diagrams, no "Scale/Div", no "Ref Pos", and no "Max" and "Min" values
can be defined.
The default scale is activated automatically when a display format (diagram type) is
selected. Scale settings that are not compatible with the current display format are
unavailable (grayed out).
Relations between the scaling parameters
The scaling parameters "Scale/Div""Ref Value", "Ref Pos", "Max", and "Min" are cou-
pled together in the following manner:
"Max" – "Min" = "Scale/Div" · <Number of graticule divisions>
"Max" = "Ref Value" when "Ref Value" is 10
"Min" = "Ref Value" when "Ref Value" is 0
Alternatives to Scaling
There are several alternatives to manual trace/diagram scaling. Refer to the following
sections:
Chapter 4.3.2, "Zooming into the display", on page 58
Chapter 4.4.4, "Touchscreen gestures", on page 79 (zoom stimulus via spreading
and pinching)
Chapter 10.2.1, "Stimulus tab", on page 311
Auto Scale Trace
Adjusts the "Scale/Div" and the "Ref Value" to display the entire active trace in the dia-
gram area, leaving an appropriate display margin.
In Cartesian diagrams, the analyzer recalculates the values of the vertical divisions
so that the trace fits onto approx. 80% of the vertical grid. The reference value is
chosen to center the trace in the diagram.
In circular diagrams ("Polar", "Smith", "Inv Smith"), the analyzer recalculates the
values of the radial divisions so that the diagram is confined to approx. 80% of the
outer circumference. The reference value is set to the value of the outer circumfer-
ence.
Auto scale does not affect the stimulus values and the horizontal axis.
Remote command:
DISPlay[:WINDow<Wnd>]:TRACe<WndTr>:Y[:SCALe]:AUTO
Auto Scale Diagram
Adjusts the "Scale/Div" and the "Ref Value" to display all traces in the diagram area,
leaving an appropriate display margin. All traces in the active diagram are scaled inde-
pendently (see "Auto Scale Trace" on page 317), and irrespective of their channel
assignment.
Scale softtool

Table of Contents

Related product manuals