CALCulate<Chn>:LIMit:TTLout<Pt>[:STATe] <Boolean>
Switches the TTL pass/fail signals on or off. The signals are applied to the USER
PORT as long as the active trace <Chn> is within limits, including the ripple limits.
See Chapter 14.2.1.1, "Aux. Port", on page 1110
Because the Aux. Port is not available for the R&S ZNLE, this command is not
available for these instruments.
Suffix:
<Chn>
.
Channel number used to identify the active trace
<Pt> 1 - TTL out pass 1 (pin 13 of Aux. Port connector)
2 - TTL out pass 2 (pin 14 of Aux. Port connector)
Parameters:
<Boolean> ON | OFF - TTL output signal on or off.
*RST: OFF
Example:
*RST; :CALC:LIM:CONT 1 GHZ, 2 GHZ
Define an upper limit line segment in the stimulus range
between 1 GHz and 2 GHz, using default response values.
CALC:LIM:STAT ON; TTL2 ON
Switch the limit check on and activate the TTL out pass 2 signal.
Manual operation: See "TTL1 Pass / TTL2 Pass" on page 434
CALCulate:MARKer...
The CALCulate:MARKer... commands control the marker functions. The com-
mands are device-specific and beyond what is specified in the SCPI subsystem
SOURce:MARKer....
Marker addressing
For all these commands, markers are addressed via:
1. Channel number <Chn>
The command operates on the active trace of channel <Chn>.
2. Marker number <Mk>
Selects a particular marker (ignored for reference markers).
The command operates on marker <Mk> of channel <Chn>'s active trace.
CALCulate<Chn>:MARKer<Mk>:AOFF............................................................................ 683
CALCulate<Chn>:MARKer<Mk>:BWIDth..........................................................................683
CALCulate:MARKer:COUPled[:STATe].............................................................................684
CALCulate:MARKer:COUPled:TYPE................................................................................685
CALCulate<Chn>:MARKer:DEFault:FORMat....................................................................685
CALCulate<Chn>:MARKer<Mk>:DELTa[:STATe]............................................................... 687
CALCulate<Chn>:MARKer<Mk>:EXCursion..................................................................... 687
CALCulate<Chn>:MARKer<Mk>:REFerence:EXCursion....................................................687
CALCulate<Chn>:MARKer<Mk>:EXCursion:STATe........................................................... 688
VNA command reference

Table of Contents

Other manuals for R&S ZNL Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ZNL Series and is the answer not in the manual?

R&S ZNL Series Specifications

General IconGeneral
BrandR&S
ModelZNL Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals