Command reference
R&S
®
ZNL/ZNLE
744User Manual 1178.5966.02 ─ 20
Example: See CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam
Manual operation: See "DC Value" on page 364
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:EXTRapolate
Extrapolates the measured trace towards f = 0 and overwrites the current DC value
(CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam). The command is rele-
vant for low pass time domain transforms.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Example: See CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam
Usage: Event
Manual operation: See "DC Value" on page 364
CALCulate<Chn>:TRANsform:TIME:LPFRequency
Calculates the harmonic grid for low pass time domain transforms, keeping the stop
frequency and the number of points.
Tip: Use CALCulate<Chn>:TRANsform:TIME:LPASs if you wish to use one of the
other algorithms for calculating the grid.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Example: See CALCulate<Chn>:TRANsform:TIME[:TYPE]
Usage: Event
Manual operation: See "DC Value" on page 364
CALCulate<Chn>:TRANsform:TIME:RESolution:EFACtor <REfactor>
Defines the resolution enhancement factor for the time domain transform.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<REfactor> Resolution enhancement factor.
Range: 1 to 10.
Increment: 0.1
*RST: 1 (no resolution enhancement)
Example: See CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam
Manual operation: See "Resolution Enh." on page 363
VNA command reference