R&S
®
ZVA / R&S
®
ZVB / R&S
®
ZVT Command Reference
SCPI Command Reference
Operating Manual 1145.1084.12 – 30 1052
The GPIB address is factory-preset. *RST has no effect on the value.
Confirmed, command or query
SYST:COMM:GPIB:ADDR 10
Set the GPIB address to 10.
*RST; :SYST:COMM:GPIB:ADDR?
After a reset, the address is maintained (the response is 10).
SYSTem:COMMunicate:GPIB[:SELF]:RTERminator LFEoi | EOI
Sets the receive terminator of the analyzer. The receive terminator indicates the end of a command or a
data block.
The receive terminator setting is relevant if block data is transferred to the analyzer (FORMat[:DATA]
REAL). In the default setting LFEOI, the analyzer recognizes an LF character sequence with or without the
EOI control bus message as a receive terminator. An accidental LF in a data block can be recognized as a
terminator and cause an interruption of the data transfer.
The EOI setting is especially important if commands are transferred in block data format, because it
ensures that the parser for command decoding is activated by the terminator only after the command has
been completely transferred. Readout of binary data does not require a change of the receive terminator.
LF character sequence with or without EOI recognized
Device-specific, command or query
SYST:COMM:GPIB:RTER EOI
Set the terminator to EOI.
SYSTem:COMMunicate:NET:HOSTname '<host_name>'
Queries or sets the analyzer's host name (computer name). The domain is not included.
Host name (string variable)
Device-specific, command or query
SYSTem:COMMunicate:NET:HOSTname?
Query the hostname of the analyzer.