R&S
®
ZVA / R&S
®
ZVB / R&S
®
ZVT Command Reference
SCPI Command Reference
Operating Manual 1145.1084.12 – 30 629
*RST; :CALC:LIM:CONT 1 GHZ, 1.5 GHZ
Define an upper limit line segment in the stimulus range between 1 GHz and 1.5
GHz, using default response values.
CALC:LIM:DATA 1,1500000000, 2000000000,2,3
Define an upper limit line segment in the stimulus range between 1.5 GHz and 2
GHz, assigning response values of +2 dB and +3 dB.
CALC:LIM:DISP ON
Show the limit line segment in the active diagram.
CALCulate<Chn>:LIMit:DELete:ALL
Deletes all limit line segments.
Channel number used to identify the active trace.
Device-specific, no query.
*RST; :CALC:LIM:CONT 1 GHZ, 1.5 GHZ
Define an upper limit line segment in the stimulus range between 1 GHz and 1.5
GHz, using default response values.
CALC:LIM:DATA 1,1500000000, 2000000000,2,3
Define an upper limit line segment in the stimulus range between 1.5 GHz and 2
GHz, assigning response values of +2 dB and +3 dB.
CALC:LIM:DEL:ALL
Delete both created limit line segments.
CALCulate<Chn>:LIMit:DISPlay[:STATe] <Boolean>
Displays or hides the entire limit line (including all segments) associated to the active trace.
Channel number used to identify the active trace.
ON | OFF - Limit line on or off.
Device-specific, command or query.
*RST; :CALC:LIM:CONT 1 GHZ, 2 GHZ
Define an upper limit line segment in the stimulus range between 1 GHz and 2
GHz, using default response values.
CALC:LIM:DISP ON