Reference oscillator
R&S
®
SMB100B
188User Manual 1178.3711.02 ─ 08
Remote command:
[:SOURce]:ROSCillator:EXTernal:NSBandwidth? on page 504
Minimum Locking Range
Indicates the minimum locking range for the selected External Reference Frequency
and the Synchronization Bandwidth.
Remote command:
[:SOURce]:ROSCillator:EXTernal:MLRange? on page 503
8.3 Reference output settings
Access:
1. Select "Frequency" > "Reference Frequency".
2. Select "Reference Output".
In the "Reference Output" tab, you can set the reference frequency value at the
output connectors.
As a result of parameter dependencies, "Preset This Parameter" sometimes does
not affect output dialogs.
The remote commands required to define these settings are described in Chap-
ter 12.15.11, "SOURce:ROSCillator subsystem", on page 500.
Settings:
Reference Output/1 GHz Reference Output............................................................... 188
Show Connector..........................................................................................................189
Reference Output/1 GHz Reference Output
Selects frequency reference output signal for downstream instruments.
"Off"
Deactivates the reference signal output.
"10 MHz"
Derives a signal with 10 MHz frequency from the internal reference
oscillator and provides this signal at the output.
"100 MHz"
Option: R&S SMBB-B3
Provides the 100 MHz reference frequency signal at the output.
"1 GHz"
Option: R&S SMBB-B3
Provides the 1 GHz reference frequency signal at the output.
"Input Signal (loop through)"
Passes the external reference frequency to the output directly.
Reference output settings