LOOPthrough
If [:SOURce]:ROSCillator:EXTernal:FREQuency 1GHZ,
forwards the input reference frequency to the reference fre-
quency output.
*RST: n.a. (factory preset: OFF)
Example: See Example"Configuring the reference oscillator" on page 501.
Options: DER1G requires R&S SMBB-B3
Manual operation: See "Reference Output/1 GHz Reference Output" on page 188
[:SOURce]:ROSCillator[:INTernal]:ADJust:VALue <Value>
Specifies the frequency correction value (adjustment value).
Parameters:
<Value> integer
*RST: 0
Example: See [:SOURce]:ROSCillator[:INTernal]:ADJust[:
STATe] on page 505
Manual operation: See "Adjustment Value" on page 189
[:SOURce]:ROSCillator[:INTernal]:ADJust[:STATe] <State>
Determines whether the calibrated (off) or a user-defined (on) adjustment value is
used for fine adjustment of the frequency.
Parameters:
<State> 1 | ON | 0 | OFF
0
Fine adjustment with the calibrated frequency value
1
User-defined adjustment value.
The instrument is no longer in the calibrated state.
The calibration value is, however, not changed. The instrument
resumes the calibrated state if you send
SOURce:ROSCillator:INTernal:ADJust:STATe 0.
*RST: n.a. (factory preset: 0)
Example: See Example"Configuring the reference oscillator" on page 501.
Manual operation: See "Adjustment Active" on page 189